Brand | Epever |
MPPT Solar Charge algorithm maximises conversion efficiancy up to 99.5%. Battery Charging function configurable to suit local environment preferences and reliabilty requirements in multiple priority modes:
Inverter DC-AC module uses SPWM to produce Pure Sine wave output suitable for residential and commercial /scientific applications.
AC Inverter Module can be configured to run on:
Control and Monitoring : Large 4.2 inch inbuilt display with realtime opertional data. Control and Monitor the system with PC Software or Android App.
Electrical Specification:
| UPower Series /Model Number | 3 KVA/ (UP3000-M3322) |
|---|---|
| System Battery Voltage (and Range) | 24 V DC (21.6~32VDC) |
| Output Power (15min.) | 3000W (Continous 2400W) |
| Max. Surge Power | 6000W |
| Inverter Output Voltage /Frequency | 220VAC±3%, 230VAC (-7%~+3%) /50Hz/60Hz |
| Inverter Output Wave | Pure Sine Wave |
| Distortion THD | ≤3% (12V or 24V resistive load) |
| AC Utility Input Voltage | 160VAC~280VAC(Working voltage range), 170VAC~270VAC(Utility starting voltage range) |
| Max. Utility Charge Current | 30A |
| Max. PV Open Circuit Voltage | 92V |
| Max. PV Input Power | 780W |
| Max. PV Charging Current | 30A |
| Battery Type | Lead Acid (AGM /Gel /Sealed /Flooded) /User Custom Battery Voltage Settings (e.g. Lithium*, etc.) |
| Battery (Equalization/Boost/Float) Voltage | 29.2 V /28.8 V /27.6 V |
| Temperature Compensation Coefficient | -3mV/℃, 2V (Default) |
| MPPT Tracking Efficiency | upto 99.5% |
| PC Connectivity Option | RS485 Interface |
| Inbuilt Relay Interface | Can drive resistive loads 125VAC /1A, 30VDC/1A. Relay triggered by battery voltage sensing parameters DON /DOF (See manual). |
Environment Specification:
| Operating Temperature Range | -20°C ~ +50°C |
| Relative Humidity | ≤95%, N.C |
| Enclosure | IP30 |
Physical Specs:
| Parameter | |||
|---|---|---|---|
| Dimension | 444×300×126mm | ||
| Mounting Dimension | 230mm | ||
| Mounting Hole Size | Φ8mm | ||
| Weight | 9.2kg | ||
Full Protection Functions:
PV Over Current, PV Short Circuit, Night Reverse charging, Battery & PV reverse polarity, Battery over discharge, Battery over heat, Battery over voltage, Load Short Circuit, Load Overload, and Device overheating. Note: To comply with IEC62109 requirement, connector for battery temp sensor is now located inside the unit.
CE, RoHS.
Box Contains:
Brand | Epever |
Պատվիրե՞լ եք մինչև ժամը 20:00-ն։ Վաղը կառաքենք։
Ժամը 20:00-ից հետո կատարված պատվերները կընդունվեն հաջորդ օրերի համար։
Առաքման ժամանակը.
«Ստանդարտ առաքում» նշանակում է հաջորդ օրը մինչև ժամը 20:00-ն կատարված պատվերների համար։ Ժամը 20:00-ից հետո կատարված պատվերները կընդունվեն հաջորդ օրերի համար։ Լրացուցիչ տեղեկությունների համար խնդրում ենք կապվել խանութների վաճառքի աշխատակիցների հետ։
Զանգահարեք և մեր մասնագետը կօգնի Ձեզ ապրանքների ընտության մեջ
(099) 200 110